Short answer: autoclaved aerated concrete (AAC) is a factory product cured in a pressurised steam autoclave and sold as blocks or panels; foam concrete (CLC) is mixed on site or in a small plant and placed as a wet mix. AAC gives you a repeatable block with a known strength grade. Foam concrete gives you a monolithic, self-levelling fill that can go where blocks cannot. Choose by what you are building, not by which is “better”.
Most comparisons online either describe AAC alone or treat the two as the same material. They are not: one is a masonry unit, the other is a placing method. That difference drives every downstream decision, from the tender document to who does the work.
The one-line difference: autoclave versus site mixing
AAC starts with sand or fly ash, lime, cement, gypsum and aluminium powder as the expanding agent. The mix rises in a mould, is cut to size on a wire line, and then cured for hours under steam pressure. The autoclave is what gives AAC its dimensional stability and its consistent strength grade, and it is also why AAC only exists as a factory product.
Foam concrete skips the autoclave entirely. A cement or cement-sand slurry is blended with pre-formed foam and placed while wet. No pressure curing, no cutting line, no mould. Density is set by how much foam goes in, and air curing does the rest.
Density and strength, side by side
| Property | Foam concrete (CLC) | Autoclaved aerated concrete (AAC) |
|---|---|---|
| Typical dry density | 400–1,600 kg/m³ (industry range) | 300–700 kg/m³ for common block grades |
| Typical compressive strength | 0.5–10 MPa depending on density and mix | 2–7 MPa across standard grades |
| Form delivered | Wet mix, poured or pumped in place | Blocks, lintels, panels, cut to fixed dimensions |
| Dimensional tolerance | Set by the formwork or the slab | Factory tolerance, typically a few millimetres |
| Curing | Air cure on site, days | Autoclave, hours, before dispatch |
| Shrinkage behaviour | Higher; needs mix and curing control | Lower and predictable |
| Where it is made | On site or in a small local plant | In a capital-intensive factory |
The ranges above are industry norms. Specific strength at a specific density depends on cement content, foam quality and curing, so any supplier quoting a single strength figure without a density figure is giving you half of the number. Our density-to-strength chart sets out how the two move together.
Where foam concrete wins
Foam concrete is a placing material, and it wins wherever the job is a void, a slope, or an irregular shape:
- Roof insulation and slope screeds. Poured to falls in one operation, with no cutting and no joints to align.
- Floor levelling and filling. Over uneven structural slabs, over old floors before a new finish, and in service trenches that need a light fill rather than granular material.
- Backfill against structures. Low density reduces lateral pressure on retaining walls and basement walls, which is often the deciding factor rather than thermal performance.
- Void filling and abandoned pipes. It flows into spaces where no block will fit.
- Single-storey walls in remote locations. Where transporting blocks costs more than mixing on site.
In all of these, the absence of joints is a functional advantage, not a cosmetic one. A monolithic pour has no mortar lines to lose insulation value or to crack differentially.
Where AAC wins
AAC wins on repetition. Once a wall design repeats across floors, the factory product’s tolerances pay for themselves in thinner mortar joints, faster laying and predictable finishes. Three situations make AAC the obvious choice:
- Multi-storey wall construction with repeated layouts. Blocks arrive cut, cured and graded; the crew lays them the same way on every floor.
- Projects with a fire or acoustic rating to demonstrate. A factory product comes with test data for a named grade, which is easier to submit than a site-mixed design.
- Programmes where wet trades are the bottleneck. Blocks can be laid as soon as they arrive and do not need curing time on the critical path.
The trade-off is handling and transport. AAC is light for its volume but it is still a unit-by-unit operation, and on a site with poor access the crane and transport cost can erase the material advantage.
Cost comparison: compare per cubic metre placed
Block price per cubic metre and foam concrete cost per cubic metre are not comparable numbers, because one includes labour to lay and the other does not. Build the comparison on placed cost:
| Cost element | Foam concrete | AAC blockwork |
|---|---|---|
| Material | Cement, sand or fly ash, foaming agent | Blocks, mortar, ties, lintels |
| Plant | Foam generator and mixer or pump, amortised or hired | Mixer, cutting tools, lifting |
| Labour | Small crew, continuous pour | Masonry crew, output measured in m² per day |
| Finishing | Surface usually needs a levelling screed or render | Render both faces, plus joint treatment |
| Waste | Low on simple shapes, higher on complex formwork | Cutting waste, typically a few percent |
| Speed | Fast for large volumes | Faster for small, repeated wall areas |
On a 200 m² roof with a slope to falls, foam concrete usually wins on labour alone. On 2,000 m² of identical internal partitions across five floors, AAC usually wins. The grey zone is single-storey housing, where local material prices decide it.
Specifying: the numbers to put in the tender
Whichever route you choose, a specification that names only the product invites substitution. Name the performance:
- Density at placement and density at 28 days, stated separately.
- Compressive strength at a stated density, with the test method.
- Thermal conductivity at that density, not a generic figure.
- For foam concrete: foaming agent dilution and the foam stability requirement, which is what separates a mix that holds its volume from one that collapses in the form.
- For AAC: the strength grade and the tolerance class.
- Curing regime and the earliest date for following trades.
Foam concrete specifications that omit density at placement are the most common source of disputes, because the same mix design can be delivered at two different densities by changing the foam ratio. Our mix ratio tables by density give the batch proportions for each target.
Can the two be used together?
Often they should be. A common and sensible detail is AAC blockwork for the walls plus foam concrete for the roof screed, the floor build-up and the service voids. The blockwork gives you a wall with a rated strength and a known finish; the foam concrete removes the awkward cutting and the joint alignment in the horizontal elements. Specifying both is not indecision, it is matching each material to the shape it handles well.
FAQ
Is foam concrete as strong as AAC?
At the same density, foam concrete can reach comparable strength, but the achievable range is wider and depends more on mix control. AAC’s strength is fixed by its grade at the factory. At very low densities both are insulation materials rather than structural ones, and neither should be used as a load-bearing wall without an engineer’s check.
Can foam concrete replace AAC blocks in a wall?
It can form a wall in low-rise construction, poured against formwork, but it is rarely the cheaper option for repeated vertical walls and it brings shrinkage and finish risks that blockwork does not. For load-bearing walls, use it only with a designed mix and an engineer’s approval.
Which one is cheaper?
Per cubic metre placed, foam concrete is usually cheaper for roofs, fills and screeds in volumes above a few cubic metres, because the labour is a small continuous crew. AAC is usually cheaper for repeated partition walls. Local block prices and the cost of transporting a foaming unit to site can reverse either conclusion.
Does foam concrete need an autoclave?
No. That is the defining difference. Foam concrete cures in air at ambient temperature, which is why it can be produced on site. The absence of autoclaving is also why its properties vary more between batches and why curing control matters more than it does for AAC.
If the decision is between pouring and laying on a specific project, send us the element, the area, the target density and the site’s power and water situation. We will tell you which route the equipment supports and what the mix needs to look like. See the foam concrete and pumping equipment range.