Foaming Agent Ratio and Dilution for Foam Concrete

Dilution ratio is a setting, not a recipe. What determines the mix is the density of the foam you inject, and that comes from three numbers working together: the concentration of agent in the solution, the expansion ratio of the generator, and the foam density you measure at the nozzle. Most protein-based agents are diluted somewhere between 1:30 and 1:50, but the ratio is only correct if the resulting foam weighs what your target density needs.

Buyers ask for “the ratio” expecting a single figure, then discover that the same agent, at the same dilution, produces different foam on two machines and in two climates. The method below replaces the ratio with a measurement you can take on site in two minutes.

Three numbers control the mix, and only one of them is a dilution

Agent concentration in the solution. Expressed as 1:30, 1:40 and so on, meaning one part concentrate to that many parts water by volume. Weaker solutions make wetter, heavier foam; stronger solutions make stiffer foam that costs more per cubic metre.

Expansion ratio. The volume of foam produced from one volume of solution. A generator running at 15× turns 1 litre of solution into 15 litres of foam. Higher expansion means lighter foam and less water carried into the mix, but too high a ratio gives coarse bubbles that collapse under the weight of the slurry.

Foam density. The mass of one cubic metre of finished foam, typically 50–90 kg/m³ for cast foam concrete. This is the number that connects the generator setting to the mix design, and it is the one almost nobody measures.

Change any one of the three and the delivered density moves. That is why a mix that worked last month can arrive 60 kg/m³ heavy this month with the same drum of agent.

Where 1:30 comes from, and when it is wrong

Protein-based agents generally want more water to develop a stable bubble film, so 1:30 to 1:40 is common. Synthetic and composite agents often run at 1:40 to 1:60 because the surfactant is more soluble and foams readily at lower concentration. Hard water, cold water and high ambient temperature all reduce foam stability and push you toward a slightly stronger solution or a lower expansion ratio.

Treat the supplier’s recommended concentration as the starting point for a trial, not a permanent setting. Dilute to the recommendation, measure the foam density, then adjust the generator’s air or solution flow until the foam weighs what the mix needs. Adjusting dilution first is the slower route and costs more agent.

From target density to litres of concentrate

The volume method is simple enough to do on a phone. Foam volume per cubic metre of finished concrete is one minus the volume taken by the base slurry:

Foam volume (m³ per m³) = 1 − (target dry density ÷ slurry density)

Slurry density for a cement-sand base mix usually falls between 1,750 and 1,850 kg/m³. Use your own measured figure if you have one. Then convert foam volume into solution and concentrate:

Solution (litres) = foam volume × foam density (kg/m³), since one litre of solution weighs about one kilogram.

Concentrate (litres) = solution ÷ (dilution ratio + 1).

The table applies that arithmetic with a slurry density of 1,800 kg/m³ and foam at 70 kg/m³. These are worked examples, not a universal dosage: run the formula with your own slurry and foam figures.

Target dry density Foam per m³ Solution needed Concentrate at 1:30 Concentrate at 1:40
400 kg/m³ 0.78 m³ 54 L 1.76 L 1.33 L
600 kg/m³ 0.67 m³ 47 L 1.51 L 1.14 L
800 kg/m³ 0.56 m³ 39 L 1.26 L 0.95 L
1000 kg/m³ 0.44 m³ 31 L 1.00 L 0.76 L

Two conclusions follow. Lighter mixes need more foam, so they consume more agent per cubic metre — the opposite of what buyers often assume when they compare a 400 and an 800 mix. And a 1:40 dilution uses roughly a quarter less concentrate for the same foam volume, which is worth knowing before you accept a quoted consumption figure.

The number in the last column is a material cost input, not a purchase quantity. Add the trial batches, the foam you dump while setting up, and the losses from generator cleaning, then round up.

Measuring foam density with a cup and a scale

A one-litre container and a kitchen scale settle most arguments. Fill the cup level with fresh foam from the nozzle, strike off the top, weigh it, and subtract the cup’s own weight. Grams per litre multiplied by 1,000 gives kg/m³. A cup that weighs 70 g of foam is delivering 70 kg/m³.

Do it three times, at the start, middle and end of a run. Variation of more than about 10% across the three readings means the generator or the solution feed is drifting, and the mix will drift with it.

Check drainage at the same time. Fill a clear container, note the level, and see how much liquid collects at the bottom after 10 and 30 minutes. Foam that releases water quickly will collapse in the mixer and leave you with a heavy, segregated pour.

Symptoms that point at the foam, not the mix

What you see Likely cause First thing to change
Delivered density 50–100 kg/m³ above target Foam too wet or too little of it Measure foam density; reduce solution concentration or raise expansion
Mix collapses after placing Unstable foam, coarse bubbles Lower expansion ratio, check generator and agent concentration
Water pooling on the surface Excess water in the foam or the slurry Cut slurry water before cutting foam
Strength below expectation at correct density Coarse voids, high water-cement ratio Foam quality and sand content, not more cement
Foam will not form at all Blocked filter, wrong agent, hard water Clean the generator, confirm the agent is diluted and in date

Note the pattern: in four of the five rows the fix is a foam or water adjustment, not more cement. Adding cement to recover strength in a wet mix usually raises density and cost without fixing the void structure.

Correcting density during a pour

Density is easiest to control at the foam valve. If the first batches come out heavy, increase foam output slightly and re-measure rather than adding water to the slurry. Water changes the water-cement ratio, which changes strength and shrinkage; foam changes only the void volume, which is the variable you are trying to control.

Record the foam density, the dilution and the delivered wet density for every pour. After a few weeks you will have the correlation for your machine and your local materials, and the settings stop being guesswork. For the batch proportions that sit on top of those settings, the mix ratio table by density gives a starting point per cubic metre.

Frequently asked questions

What dilution ratio should I use for foam concrete?

Start at 1:30 for protein-based agents and 1:40–1:50 for synthetic types, then adjust until the measured foam density matches the target. The ratio is a means to that end, and it will shift with water hardness, temperature and generator condition.

How much foaming agent do I need per cubic metre?

It depends on target density and dilution, but the calculation is short: foam volume is one minus target density divided by slurry density, and concentrate follows from the foam density and dilution. At 600 kg/m³ with 1:30 dilution, a typical case lands near 1.5 litres per cubic metre. Confirm against a trial batch before ordering.

Can I use washing-up liquid instead of a foaming agent?

No. Detergent foams readily but the bubbles are unstable and collapse under the weight of cement slurry, so you lose the density you designed for and get a wet, segregated pour. Purpose-made protein or synthetic agents are formulated to hold a film in a alkaline cement environment.

Does more foam always mean a lighter mix?